The Ministry of Construction and Architecture of Belarus adopted a resolution dated 14 October 2026 No. 89, which approved changes to the construction norms SN 3.02.01‑2019 “Residential Buildings.” The ministry’s press office explained the key innovations.

The new norms will come into force on 18 January 2027. They concern requirements for studio apartments, room heights, sanitary facilities, vestibules, as well as balcony and loggia enclosures. The document was developed taking into account proposals from developers, design organizations, and citizens.

The area restriction for studio apartments is being removed. Previously it could not exceed 50 square metres. The innovation will broaden design possibilities.

The overall requirement for room height has been clarified — it must be 2.5 metres (for living rooms). This will allow proper consideration of attic floors, where the entire area within the roof‑slope zone cannot realistically sustain such a height.

Regarding sanitary facilities and bathrooms, partial placement (up to 50 %) of one of the sanitary rooms above a living room is allowed — provided that the floor of the sanitary room has enhanced hydro‑ and sound insulation. The previous edition allowed only 25 %. The specific requirement for one of the dimensions in the bathroom plan (combined sanitary room) has been replaced by a mandatory requirement that ensures the possibility of installing sanitary and technical equipment.

The requirement to install vestibules in single‑apartment residential buildings and in apartments of blocked residential buildings has been eliminated, as well as double vestibules in buildings 12 floors high and above.

The requirements for balconies and loggias have been clarified. To fill the non‑opening lower part of the glazing, non‑opening lower window sashes, the use of double‑glazed units with an inner layer of multi‑layer safety glass is prescribed. The height of enclosures located below the windows of wall sections has been set uniformly at 1.1 metres. This eliminates the semantic inconsistency in the requirements regarding the use of 0.9 metres for enclosures and 1.1 metres for non‑opening sashes.